Goulds Submersible Sewage Pump
FEATURES
- Impeller: Cast iron, semi open, non-clog with pump out vanes for mechanical seal protection. Balanced for smooth operation. Silicon bronze impeller available as an option.
- Casing: Cast iron volute type for maximum efficiency. 2" NPT discharge, adaptable for A10-20 slide rail systems.
- Mechanical Seal: SILICON CARBIDE VS. SILICON CARBIDE sealing faces, stainless steel metal parts, BUNA-N elastomers.
- Shaft: Corrosion-resistant stainless steel. Threaded design. Locknut on three phase models to guard against component damage on accidental reverse rotation.
- Motor: Fully submerged in high grade turbine oil for lubrication and efficient heat transfer.
- Designed for Continuous Operation: Pump ratings are within the motor manufacturers recommended working limits, can be operated continuously without damage.
- Bearings: Upper and lower heavy duty ball bearings construction.
- Power Cable: Severe duty rated, oil and water resistant. Epoxy seal on motor and provides secondary moisture barrier in case of outer jacket damage and to prevent oil wicking.
- 0-ring: Assures positive sealing against contaminants and oil leakage.
- Fasteners: All stainless steel
APPLICATIONS
Specifically designed for the following uses:
- Homes
- Sewage Systems
- Dewatering
- Water Transfer
SPECIFICATIONS
Pump:Solids handling capability: 1 1/2" maximum.
Capabilities: up to 140 GPM.
Total heads: up to 26 feet TDH.
Discharge size: 2" NPT.
Mechanical seal: silicon carbon-rotary/silicon-carbide stationary, BUNA-N elastomers.
Temperature: 104O F (40OC) continuous 140O F (60OC) intermittent.
Fasteners: 300 series stainless steel.
Capable of running dry without damage to components.Motor: Single phase: 1/2 HP, 115V, 200V, or 230V, 60 Hz, 1750 RPM, built in overload with automatic reset.
Three phase: 1/2 HP, 200/230/460V, 60 Hz, 1750 RPM
Class B insulation
Overload protection must be provided in starter unit.
Shaft: threaded 400 series stainless steel.
Bearings: ball bearings - upper and lower.
Power cord: 20 foot standard length (optional lengths available)
Single phase: 16/3 SJTO with three prong plug.
Three phase: 14/4 STO with bare leads.
On CSA listed models: 20 foot length SJTW or STW are standard.
Item No. Description 1
Impeller 2
Casing 3
Mechanical seal 4
Shaft 5
Motor 6
Bearings upper and lower 7
Power Cable 8
0-ring
DIMENSIONS
(All dimensions are in inches. Do not use for construction purposes.)
Order No. |
HP | Volts | Phase | Max.Amps | RPM | 3g Heater Size |
Wts.(lbs.) |
| WS0511A | 1/2 | 115 | 1 |
13.0 | 1750 | N/A |
60 |
| WS0512A | 230 | 6.5 | |||||
| WS0518A | 200 | 7.5 | |||||
| WS0538A | 200 | 3 |
3.8 | K32 | |||
| WS0532A | 230 | 3.3 | K31 | ||||
| WS0534A | 460 | 1.6 | K21 |
PERFORMANCE RATINGS |
||
Order No. |
WS0511A |
|
HP |
1/2 |
|
RPM |
1750 |
|
| Total Head Feet of Water |
5 | 138 |
| 10 | 107 |
|
| 15 | 74 |
|
| 20 | 40 |
|
| 25 | 8 |
|